D3645-US Rev D July 12, 2006
StockWeigh 550 EID
StockWeigh 550 EIDStockWeigh 550 EID
StockWeigh 550 EID
& StockWeigh Link
& StockWeigh Link& StockWeigh Link
& StockWeigh Link
OPERATORS MANUAL
Fort Atkinson, Wisconsin USA
Helden-Beringe, The Netherlands
www.digi-star.com
Zobrazit stránku 0
1 2 3 4 5 6 ... 37 38

Shrnutí obsahu

Strany 1 - StockWeigh 550 EID

D3645-US Rev D July 12, 2006 StockWeigh 550 EIDStockWeigh 550 EIDStockWeigh 550 EIDStockWeigh 550 EID & StockWeigh Link& StockWe

Strany 2

StockWeigh 550 EID and StockWeigh Link 6LKNHLD Lock-N-Hold This feature continues to hold the Lock-On weight on the display for an animal after i

Strany 3

Operators Manual D3645 7 AUTPRT Automatic Print - Indicator does not accept EID data. - Indicator does not store data in memory. - Sends Time, Dat

Strany 4

StockWeigh 550 EID and StockWeigh Link 8AUTEID Automatic EID - Indicator accepts EID data. - Message alerts operator if EID data is missing. -

Strany 5

Operators Manual D3645 9 LSSEND Lock-On-Store Send - LSSEND is for LSTORE automatic modes and has no effect in manual modes. - If set to “OFF”, d

Strany 6

StockWeigh 550 EID and StockWeigh Link 10 DATE Set Date Use the [NET/GROSS] key to increment each digit and use the [TARE] key to advance the bli

Strany 7

Operators Manual D3645 11ARANGE Auto-Range If “ON” the scale increases display count size for weights over 300 and again at 600 lbs/kgs. If set to

Strany 8 - Optional Settings

StockWeigh 550 EID and StockWeigh Link 12StockWeigh Link PC Software StockWeigh Link software can be configured to automatically or manually

Strany 9

Operators Manual D3645 13Installing the StockWeigh Link PC Software The StockWeigh Link PC software is shipped to you on a CD. To install the soft

Strany 10

StockWeigh 550 EID and StockWeigh Link 14FILES/Setup Options This command opens a dialog box to enable the operator to configure the software. T

Strany 11 - Operators Manual

Operators Manual D3645 15Ask to Clear After Read If selected, the program will ask the operator “Do you wish to clear the StockWeigh 550 EID memory

Strany 12

StockWeigh 550 EID and StockWeigh Link This page intentionally left blank.

Strany 13

StockWeigh 550 EID and StockWeigh Link 16Appendix A EID Reader WARNING: The StockWeigh 550 EID connects to Allflex ISO Compatible RFID Sti

Strany 14

Operators Manual D3645 17Appendix B Weigh Methods Select weigh method #4 for animal weighing. The EID features require the indicator to be set in

Strany 15

StockWeigh 550 EID and StockWeigh Link 18Appendix C Net and Gross Mode To Select Gross Mode GROSS mode displays the weight change since the un

Strany 16 - Getting Started

Operators Manual D3645 19Appendix D Short Form Calibration NOTE: For systems with Digi-Star StockWeigh Load Cells see page 5 for setup instruction

Strany 17

StockWeigh 550 EID and StockWeigh Link 20Calibrating the Scale for Maximum Accuracy Before continuing, first write down the current SETUP and CA

Strany 18 - FILES/Setup Options

Operators Manual D3645 21To Enter a New Setup and Calibration Number Short Form Calibration The Short Form Setup & Calibration procedure allows

Strany 19

StockWeigh 550 EID and StockWeigh Link 22Appendix E Scoreboard Methods There are ten scoreboard methods available. Methods one thru six sends

Strany 20 - Appendix A

Operators Manual D3645 23Appendix F EID Data Formats Data is output thru the computer port to be stored in a computer or printed. There are many d

Strany 21 - Appendix B

StockWeigh 550 EID and StockWeigh Link 24EID CSV Data Format EID CSV Data is collected from the eartag using the EID Stick Reader and stored in m

Strany 22 - Appendix C

Operators Manual D3645 25Print Formats PRTFMT is active when “LSTORE” is set to “OFF”, “MANPRT” or “AUTPRT”. Following is a detailed explanation of

Strany 23 - Appendix D

Operators Manual Table of ContentsTable of ContentsTable of ContentsTable of Contents StockWeigh 550 EIDStockWeigh 550 EIDStockWeigh 550 EIDStoc

Strany 24 - KNOWN WEIGHT

StockWeigh 550 EID and StockWeigh Link 26 ANIMAL This CSV format includes information for animal weighing. Includes $' if unit is "l

Strany 25

Operators Manual D3645 27Definitions {cr} ASCII control code "Carriage Return". {lf} ASCII control code "Line Feed". > Re

Strany 26 - Appendix E

StockWeigh 550 EID and StockWeigh Link 28Appendix G Weighing Errors OVRCAP Capacity Limit: The display shows the message "OVRCAP" if

Strany 27 - Appendix F

Operators Manual D3645 29Appendix H Software License Agreement Digi - Star® LLC IMPORTANT: The Digi-Star® software being installed by you or by our

Strany 28 - EID CSV Data Format

StockWeigh 550 EID and StockWeigh Link 30Separate 6’ Power Cord P/N 403643 and Power Converter with 6’ Cord P/N 403526 Appendix I Scale Parts

Strany 29 - Print Formats

Operators Manual D3645 31StockWeigh Load Cells StockWeigh Load Cell Specifications Gross Capacity Model 3300: 3300 lbs

Strany 30

StockWeigh 550 EID and StockWeigh Link 32StockWeigh Alley Platform PN 403360 Scale System with StockWeigh Alley Platform

Strany 31

Operators Manual D3645 33Troubleshooting Guide Disconnect the first load cell. Connect the other load cell to the indicator (use the same connector)

Strany 32 - Appendix G

StockWeigh 550 EID and StockWeigh Link 34Index +RANGE... 29 1L PRT...

Strany 33 - Appendix H

StockWeigh 550 EID and StockWeigh Link

Strany 34 - Appendix I

Operators Manual D3645 1StockWeigh 550 EID The Digi-Star StockWeigh 550 EID indicator is designed to weigh livestock, collect EID (electronic ident

Strany 35

StockWeigh 550 EID and StockWeigh Link 2Getting Started The following steps will allow you to get familiar with your new StockWeigh 550 EID indi

Strany 36

Operators Manual D3645 3Zero Balance the Scale Press the [NET/GROSS] key and within three seconds, press the [ZERO/RECHECK] key. The ZERO/BALANCE wil

Strany 37 - Troubleshooting Guide

StockWeigh 550 EID and StockWeigh Link 4To Recheck Lock-On Weight While the animal is still on the scale platform, press the [ZERO/RECHECK] key t

Strany 38

Operators Manual D3645 5Changing Options Using Long Form Setup 1. Enter the Long Form Setup by holding [Net-Gross] and pushing [ON/Record] for three